Temperature:

 
Refrigerator / ultra-low freezer

Perfect for temperature measurement in refrigerators and freezers.
  • 4-wire DIN A temperature probe, -80°..+105°C
  • Plastic material, boilable
  • Probe diameter 5mm
  • Probe length 20mm
  • Round cable
tl_files/img/ZMS/sensor_3167.jpg





(3167)

Ultra-low freezer

Suited for the usage in ultra-low freezer.
  • 4-wire DIN A temperature probe, -90°..+260°C
  • Probe diameter 4mm
  • Probe length 100mm
  • Teflon cable
tl_files/img/ZMS/sensor_3163.jpg

(3163)

Liquid nitrogen tanks

Temperature probe for measurements down to -200°C
  • 4-wire DIN A temperature probe, -200°..+180°C
  • For autoclave and steam proofed
  • Probe diameter 5mm
  • Probe length 100mm
  • Teflon cable
tl_files/img/ZMS/sensor_3181.jpg

(3181)

Cold rooms / warehouses

A probe with a larger thermal mass for measurements in cold rooms and warehouses.
  • 4-wire DIN A ML-temperature probe, -90°C..+350°C
  • Probe stainless steel
  • Probe diameter 6mm
  • Probe length 100mm
tl_files/img/ZMS/sensor_3190.png

(3190)

Converter PT100 - 4..20mA

Programmable PT100 transmitter, for the connection of PT100 probes to an ECOLOG-NET LA8 datalogger.
  • With connector/socket M12
  • Range programmable -200°..+600°C
  • Environment temperature -40°..+85°C with mounting clip
  • Standard-programming: 0..150°C
tl_files/img/ZMS/sensor_3350A.jpg
(3350-A)

Temperature / relative air humidity:

 
General purpose sensor

Versatile temperature/humidity sensor, e.g. for warehouse or clean room monitoring.
  • Channel or wall mounting
  • Range 0..100%rH, -40°C..60°C
  • Probe length 50mm
  • Output 4..20mA
  • Accuracy humidity: +/- 2% (0..90%rH), +/- 3% (90..100%rH)
  • Accuracy temperature: PT1000 tolerance class A
  • With snap-in plate
tl_files/img/ZMS/sensor_3310.jpg
tl_files/img/ZMS/sensor_3310_2.jpg
tl_files/img/ZMS/sensor_3315.jpg

(3310/3315)

Incubators, stability chambers

Temperature and relative air humidity measurement with external probe. Used in conjunction with ECOLOG-NET LA8 dataloggers.
  • Measuring range: 0..100%rH, -40°..80°C
  • Probe length ca. 75mm
  • External T/rH probe, cable length 2m
  • Output 4..20mA
  • Accuracy humidity: +/- 2% (0..90%rH), +/- 3% (90..100%rH)
  • Accuracy temperature: by 20°C +/- 0.2°C, by 40°C +/-0.7°C, by 60°C +/- 0.6°C
  • With snap-in plate
tl_files/img/ZMS/sensor_3317.jpg
(3317)

Temperature and humidity measurement, used in conjunction with ECOLOG-NET LH2 dataloggers.
  • Measuring range: -35°..+70°C; rH: 0%..100%
  • Accuracy humidity: ±1.5% rH
tl_files/img/ZMS/sensor_3087.jpg

(3087)

CO2-measurement:

 
Incubators

Probe for measuring of CO2 concentrations in incubators.
  • Measurement range: 0..20%rH
  • IP65, for harsh and humid environment
  • External probe, cable length 2m
tl_files/img/ZMS/sensor_3271.jpg

(3271-Q) 

Room climate measurement

CO2 transmitter for wall-mounting
  • Measuring range: 0..2000 ppm
  • Wall mounting
  • Pressure differential
tl_files/img/ZMS/sensor_3271-F.jpg

(3271-F)

Clean rooms

Pressure differential sensor for clean room application.
  • Measuring range: 0..50 Pa
  • Robust metal housing
  • Linearity error: +/- 0.5% FS
  • Retry accuracy: 4% FS per year
tl_files/img/ZMS/sensor_3257.jpg

(3257-B)

Particle concentration

Particle counter with integrated vacuum pump
  • Two channels: 0.5um and 5um (other settings possible)
  • 4..20mA output
tl_files/img/ZMS/sensor_3380.jpg

(3380-A)